My first lefthand ISCSI VI architecture

1 min read

I’m currently reviewing a design of a new virtual infrastructure. The VI uses multiple 10GB links to connect to a very large HP Lefthand san. I’m more a Fibre Channel guy, but I believe that this solution will smoke most mid-range FC-sans. I cannot wait to deploy the VI on the SAN. But I need to get used to some differences between ISCSI and fibre channel configurations.

The “problem” or my latest challenge is creating a LUN provisioning scheme where multiple clusters can connect to all the LUNs when a disaster occurs and a cluster has failed. Lefthand present the LUNs as targets instead using the LUN ID as a unique identifier. I’m used to design a LUN ID scheme per cluster, this way if a cluster fails, the “destination” cluster can connect to the LUNs of the failed cluster with the same LUN ID as the original cluster.
But when a (lefthand) LUN is presented to the ESX server, it will use a unique target ID instead of a unique LUN ID. (vmhba1:2:0) I have done some testing and discovered that the assigned target ID can differ from ESX server to ESX server.
I’m curious if the target ID is used when creating the UUID of the VMFS datastore. And I’m especially interested in what will happen if multiple ESX hosts are going to communicate with the LUN when all the ESX hosts will use a different “path”
Maybe there isn’t a problem at all and different targets will work well, but is seems that I need to stop thinking in FC solutions and get used to iscsi Lefthand “quirks”.
I’ve read the field guide for VMware infrastructures, I googled on terms like “iscsi lun scheme’s” but I cannot seem to find any real-life scenario’s.
Maybe my Google skills are pitiful at the moment, and maybe someone can shed some lights on this and how they solved this “problem”.

frankdenneman Frank Denneman is the Machine Learning Chief Technologist at VMware. He is an author of the vSphere host and clustering deep dive series, as well as podcast host for the Unexplored Territory podcast. You can follow him on Twitter @frankdenneman

This blog has been hacked by vS0ciety

Follow us @vS0ciety
frankdenneman
0 sec read

Part 3 – Data path is not managed as…

Welcome to part 3 of the Virtual Datacenter scaling problems with traditional shared storage series. Last week I published an article about the FAST...
frankdenneman
6 min read

Consumer grade SSD versus Enterprise grade SSD, which one…

Should I use consumer grade SSD drives or should I use enterprise grade SSD drives? This a very popular question and I receive it...
frankdenneman
3 min read

4 Replies to “My first lefthand ISCSI VI architecture”

  1. Hey Frank,
    Nice article – please keep us updated on how you progress. I’m interested in the solution to your (possible) problem!
    KLC

  2. Thats a good question and one that I’m just discovering for myself too. We have an ESX cluster connected to several HP FC EVAs at present but we also have a large (ish) Lefthand iSCSI SAN which we want to be able to provision some data volumes for VMs. When we present multiple LUNs from the iSCSI SAN on each host they appear as LUN ID 0 but with different iSCSI target IDs? Like you, coming from a fibre world this seems strange and very off putting to me.
    I carried on doing some testing and added 3 LUNs to each node in the cluster and then created a VMFS on the first LUN. To my surprise this new VMFS worked and appears on all of the nodes that the LUN is presented to and likewise for additional VMFS disks too.
    All seems well in testing so far but if there is any difinitive answer out there I’d like to hear it.
    Paul

  3. We’ve only used iscsi and a combination of Sanmelody (single and multiple paths/HA) as well as Equallogic. While everything “just worked” I saw what you mentioned and no amount of Googling helped (as you found out).
    I even went to the point of making sure the Send Targets were in the same order on each host, nope, still the same (well different 🙂
    Be interested to know if there is a doc on this somewhere, it’s been a over a year for us now with the setup and all good!
    Ray

  4. I suppose one of the easiest ways to verify this is to test it before it goes into production. Set up the various nodes of your cluster with some test LUNs, then go yank a cable or otherwise instigate a failover and see how things work.
    Also, I’m not sure if this applies to lefthand, but I know with other vendor storage, it has been shown that NFS-connected (NAS) datastores actually get better performance than ISCSI LUNs. This may be something else to consider if you’ve got cycles to burn in your testing phase, although if you’re coming from an FC world this also may go against everything you know 🙂 (see this thread as a starting point in the debate – http://communities.vmware.com/message/737269)
    Best of luck in your deployment!